UL1977测试研读-9
返回列表 来源: 未知 发布日期:2021-08-24
今天给大家介绍一下UL1977标准的温升测试

Method:
  • The temperature measurement is to be made on the wiring terminals of each device
  • 温升测试点应布在接线端子上
  • The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time
  • 最少连续运行4个小时,即使温度在很短的时间内稳定
  • Three consecutive readings, taken at 5 minute intervals,indicate no further rise above the ambient temperature
  • 三次连续读数,每次间隔5分钟
  • All contacts are to be connected in series so as to carry the same test current.
  • 所有的端子需要串成一个回路来通相同的电流
  • Tested at a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F)
  • 测试的环境温度应保持在25 ±5°C (77 ±9°F)
  • 温升测试示意图



Result:
The measured temperature shall not exceed the Relative Thermal Index (electrical and mechanical without impact) of the insulating material
  • 最高温度不能超过塑料的RTI(Elec. and mech.without impact)
Notes:
  1. A Type 0 or Type 1A device not assigned a current rating need not be tested
  • Type 0或者Type 1A的连接器在不指定电流时可以不做温升测试
  1. For connectors with groups of contacts with different electrical ratings, each group is to be wired as a separate series circuit and tested concurrently
  • 当连接器的多种端子有不同电流时,那么每种端子的测试回路需要分开,并且同时做测试