今天给大家介绍一下UL1977标准的温升测试
Method:
-
The temperature measurement is to be made on the wiring terminals of each device
-
温升测试点应布在接线端子上
-
The test is to continue for 4 hours even if stabilized temperatures are attained in a shorter period of time
-
最少连续运行4个小时,即使温度在很短的时间内稳定
-
Three consecutive readings, taken at 5 minute intervals,indicate no further rise above the ambient temperature
-
三次连续读数,每次间隔5分钟
-
All contacts are to be connected in series so as to carry the same test current.
-
所有的端子需要串成一个回路来通相同的电流
-
Tested at a draft-free area having an ambient temperature of 25 ±5°C (77 ±9°F)
-
测试的环境温度应保持在25 ±5°C (77 ±9°F)
Result:
The measured temperature shall not exceed the Relative Thermal Index (electrical and mechanical without impact) of the insulating material
-
最高温度不能超过塑料的RTI(Elec. and mech.without impact)值
Notes:
-
A Type 0 or Type 1A device not assigned a current rating need not be tested
-
Type 0或者Type 1A的连接器在不指定电流时可以不做温升测试
-
For connectors with groups of contacts with different electrical ratings, each group is to be wired as a separate series circuit and tested concurrently
-
当连接器的多种端子有不同电流时,那么每种端子的测试回路需要分开,并且同时做测试