今天给大家介绍下UL1977的overload测试
-
Six representative devices
-
Different Type designations within a single housing
Overload Test 过载测试
-
Female device,针对female连接器
-
Test condition
Current ( A ) |
150% rated current |
Potential ( V ) |
95~105% rated voltage |
Power factor |
0.75 ~ 0.80, only for ac |
Fuse ( A ) |
15 A |
rating-current < 30 A |
30 A |
rating-current > 30 A |
Insert and withdraw with current |
50 c, < 10 c/min |
判定结果:
-
No any electrical or mechanical failure of the device nor pitting or burning of the contacts that would affect the intended function
-
连接器电气或机械结构不失败,接触件的蚀损或灼烧不影响使用功能
-
The grounding fuse not open during the test
-
测试过程中接地保险丝不能断开
Exceptions,
不需要做过载测试的情况:
-
A Type 0 device type0类型的产品
-
A device is marked in accordance with “Not for current interrupting “ or “For disconnecting use only “ or with an equivalent statement,
-
A female contact device interlocked with an integral switch or other means such that the circuit is opened before a mating male contact device can be inserted or withdrawn
德立弗检测是UL合作的TPTDP免目击实验室,拥有全套的UL1977测试能力,欢迎您的咨询!